InTemp Bluetooth Low Energy 2M Temperature Probe with 30ml Glycol Bottle Data Logger (CX402-T230)
Important Info
+Description:
Highlighted Features:
- Easy-to-read display with current and daily min/max temperatures
- Bluetooth transmission of data and alarm states
- Logger setup and download of data in seconds – without a PC or cable
- Real-time alerts and automatic data downloads with optional CX Gateway device
- +/- 0.5C accuracy for reliable temperature readings
- Battery-powered to guard against local power loss
- Several Glycol bottle/probe-only options available
Specifications
+| Logger | |
|
Radio Power |
1 mW (0 dBm) |
|
Transmission Range |
Approximately 30.5 m (100 ft) line-of-sight |
|
Wireless Data Standard |
Bluetooth Low Energy (Bluetooth Smart) |
|
Logger Operating Range |
-30° to 70°C (-22° to 158°F), 0 to 95% RH (non-condensing) |
|
Logging Rate |
1 second to 18 hours |
|
Time Accuracy |
±1 minute per month at 25°C (77°F) |
|
Battery Type |
Two AAA 1.5 V alkaline or lithium batteries, user replaceable |
|
Battery Life |
1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive report generation, numerous audible alarms, and paging all impact battery life. |
|
Memory |
128 KB (84,650 measurements, maximum) |
|
Full Memory Download Time |
Approximately 60 seconds; may take longer the farther the device is from the logger |
|
LCD |
LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range |
|
Dimensions |
9.4 x 4.5 x 2.59 cm (3.7 x 1.77 x 1.02 inches) |
|
Weight |
90.2 g (3.18 oz) |
|
Environmental Rating |
IP54 |
|
CE |
The CE Marking identifies this product as complying with all relevant directives in the European Union (EU). |
| External Temperature Probe | |
|
Range |
-40° to 100°C (-40° to 212°F) |
|
Accuracy |
±0.5°C from -15° to 80°C (±0.9°F from 5° to 176°F) ±1.0°C from -40° to -15°C (±1.8°F from -40° to 5°F) ±0.7°C from 80° to 100°C (±1.3°F from 176° to 212°F) |
|
Resolution |
0.024°C at 25°C (0.04°F at 77°F) |
|
Drift |
<0.1°C (0.18°F) per year |
|
Response Time |
With 5 mL bottle: 10 minutes typical to 90% in air moving 1 m/s With 15 mL bottle: 20 minutes typical to 90% in air moving 1 m/s With 30 mL bottle: 25 minutes typical to 90% in air moving 1 m/s |
|
Cable Length |
2 or 4 meter (6.56 or 13.12 feet) flat ribbon cable |
|
NIST Calibration |
Single-point NIST calibration, probe and logger body |
|
Probe Dimensions |
Food-grade stainless steel probe with pointed tip, 53.34 mm (2.1 inches) long, 3.18 mm (0.125 inches) diameter |
| Ambient Temperature Sensor | |
|
Range |
-30° to 70°C (-22° to 158°F) |
|
Accuracy |
±0.5°C from -15° to 70°C (±0.9°F from 5° to 158°F) ±1.0°C from -30° to -15°C (±1.8°F from -22° to 5°F) |
|
Resolution |
0.024°C at 25°C (0.04°F at 77°F) |
|
Drift |
<0.1°C (0.18°F) per year |
|
Response Time |
15 minutes typical to 90% in air moving 1 m/s |
Attributes
+| Communications | Bluetooth |
|---|---|
| Measurement | Temperature |
| Environment | Indoor |
| Product Solution | Stand-alone Data Loggers |