Two Critical Elements with One Instrument
Sindie® +Cl is a two-in-one instrument enabling trace analysis of both sulfur and chlorine with one analyzer. It is the ideal solution to certify sulfur levels in finished products, assess chlorine for corrosion mitigation, and optimize process parameters. Sindie® +Cl utilizes a technique known as Monochromatic Wavelength Dispersive X-ray Fluorescence (MWDXRF) – delivering exceptional reproducibility. Samples are measured directly, which means it can analyze even the heaviest of hydrocarbons like crude oil or coker residuals without the hassles of boats, injectors, furnaces, or changing detectors.
Your best just got better.
XOS’s next generation of analyzer provides unparalleled precision with enhanced UX, improved data management, and greater ease of use.
- LIMS integration for data management and transfer
- Custom sample presets to save data entry time and minimize data entry error on common samples
- Bar code reader auto fills sample name to reduce data entry time
- Storage capacity for more than 50,000 measurement results
- Supports up to 30 calibration curves
- USB connectivity in front and back for connecting to printer, keyboard, mouse, and memory stick
- Supports USB and network printers
- Large, easy-to-remove side panels for easy serviceability
- Advanced error reporting and diagnostics
Product Details
Applications
- Total sulfur analysis from ultra-low sulfur fuels to crudes
- Total chlorine analysis from aqueous solutions and aromatic products to heavy fuels and crudes
- For use in refinery labs, pipeline terminals, additive plants and inspection laboratories
Features
- Sulfur
- LOD: 0.4 mg/kg (ppm) at 300s, 0.28 mg/kg (ppm) at 600s*
- Dynamic Range: 0.4 mg/kg (ppm) to 5 wt%
- Chlorine
- LOD: 0.3 mg/kg (ppm) at 300s, 0.21 mg/kg (ppm) at 600s*
- Dynamic Range: 0.3 mg/kg (ppm) to 3000 mg/kg (ppm)
- Automatic sulfur correction saves time and improves accuracy and precision on high sulfur samples
- Easy to use
- Intuitive 10-inch touch screen
- Just plug in and measure
- Measurement time: 10-999 s
- Low maintenance: no gasses, or heating elements
- Traditional 43 mm XRF sample cups or XOS Accucells – decided at time of order
- Small footprint
Specifications
Test Method: ASTM D2622, D7039, D7536, D4929, ISO 20884, and SH/T 0842
Dimensions:
42 cm (h) x 40 cm (w) x 54 cm (d)
16.5 in (h) x 15.8 in (w) x 21 in (d)
Power:
100-120 VAC, 47-63 HZ at 5.0 Amps
200-240 VAC, 47-63 HZ at 2.5 Amps
Minimum Sample Cup Volume: Traditional – 5 ml, Accucell – 1 mL
Ambient Temperature Requirements: 5-40° C (40-104° F)
Excitation Source: 75 W air-cooled