Votre leader canadien en instrumentation depuis 1946.

Appareil de mesure de point d’éclair

MINIFLASH TOUCH is a uniquely designed flash point tester for the determination of flashpoint’s of liquids and solids, using the Grabner flash point detection method of measuring the instantaneous pressure increase inside the continuously closed chamber, triggered by an energy-controlled electric arc. Heating the test chamber from the top avoids condensation of high volatile compounds, significantly improving […]

Posez une question sur ce produit

MINIFLASH TOUCH is a uniquely designed flash point tester for the determination of flashpoint’s of liquids and solids, using the Grabner flash point detection method of measuring the instantaneous pressure increase inside the continuously closed chamber, triggered by an energy-controlled electric arc. Heating the test chamber from the top avoids condensation of high volatile compounds, significantly improving the test results.

Its continuously closed cup design and small sample volume of only 1-2 mL offers maximum safety, avoids offensive fumes in the testing area and reduces sample waste. The fast thermoelectric cooling at the end of a test and the fast and easy handling of the instrument save expensive labor time.


Features

  • Flashpoint according to ASTM D6450 (Flash-Point by Continuously Closed Cup) and ASTM D7094 (Flash-Point by Modified Continuously Closed Cup)
  • FLASHPOINT COMMITTEE STATEMENT: "There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A."), equivalent EN ISO 2719, excellent correlation to ASTM D56, ISO13736, IP170
  • Approved for Diesel Fuel and Kerosene specifications ASTM D975, D396, D2880, D3699
  • New methods for EN ISO 3679 and EN ISO 3680 simulation
  • Dilution Flashpoint Testing
  • Go / No Go Flashpoint Testing
  • Fast Screening Methods
  • Automatic ignition cleaning method
  • Maximum safety through Grabner continuously closed cup method (Ignition Protection Technology™)
  • 1-2 ml sample size
  • No Open Flame, no offensive vapors in the lab
  • Highest accuracy (see precision statement)
  • Extended temperature range: 0 to 400°C with external cooling (MINIFLASH FLPH TOUCH)
  • Fully remote operable
  • Big, colour touch-screen for convenient, intuitive menu navigation
  • Touch Screen Runs on Microsoft® Windows®: Full integration with network, LIMS and PC
  • Hassle-free communication and data transfer via USB and Ethernet
  • USB printer support
  • Good Laboratory Practice: User Access Control
  • Portable for Mobile and Field Use (car battery connector)
  • Worldwide standard method for the flavors and fragrances industry
  • Approved for the ASTM specifications of recycled fuel and biodiesel
  • Short measuring time (depends on sample type) due to small sample volume of 1-2 ml
  • Combustion Analysis™
  • Excellent thermoelectric heating and cooling regulation through Peltier Protection Technology™