Wire Size Conductor Size Insulation Thickness Jacket Thickness Outer Diameter Net Weight AWG MM Inch […]
Wire Size
Conductor Size
|
Insulation Thickness
|
Jacket Thickness
|
Outer Diameter
|
Net Weight
|
||||
AWG
|
MM
|
Inch
|
MM
|
inches
|
|
inches
|
MM
|
kg/km
|
20
|
0.81
|
0.015
|
0.38
|
0.015
|
0.38
|
.092 x .154
|
2.3 x 3.9
|
21
|
Standard Roll Sizes (other lengths available upon request)
M
|
ft
|
30.5
|
100
|
305
|
1000
|
Available Thermocouple Wire Types
T, J, K
Specifications
Conductors: Solid or stranded thermocouple wire per ASTM E230 & ANSI MC96.1
Insulation: Flame retardant PVC
Construction: Parallel conductors
Jacket: Flame retardant PVC
Operating Temperature: -15F (-26C) to +221F (+105C) continuous
Limits of Error: Conforms to ASTM E230 and ANSI MC and ANSI MC 96.1
Colour Code: Conforms to ASTM E230, IEC 584 96.1 (International Color Codes Available)
Thermocouple | Temperature Range F | Standard Grade Limits | ||
Extension Grade Wire | F (C) | F (C) whichever is greater | ||
TX | 32 (0) to 212 (100) | ±1.8 (1) | ||
JX | 32 (0) to 400 (200) | ±4 (2.2) | ||
KX | 32 (0) to 400 (200) | ±4 (2.2) | ||
Special Grade Limits | ||||
F (C) whichever is greater | ||||
TTX | 32 (0) to 212 (100) | ±0.9 (0.5) | ||
JJX | 32 (0) to 400 (200) | ±2 (1.1) | ||
KKX | 32 (0) to 400 (200) | ±2 (1.1) |