The Palmer Bowlus metering flume has been widely used for measuring water and wastewater in open channels or pipelines that are not under any pressure. This flume is normally installed in a "U" shaped channel fed by a pipeline such as storm drains and sewers. This convenient flume requires little redesign or special modification of […]
The Palmer Bowlus metering flume has been widely used for measuring water and wastewater in open channels or pipelines that are not under any pressure. This flume is normally installed in a "U" shaped channel fed by a pipeline such as storm drains and sewers. This convenient flume requires little redesign or special modification of circular conduits for installation.
Rather than try to make the flow application fit a particular type of flume, we carefully analyze the parameters so we can select an appropriate flume for the application. Options and modifications are available to ensure that the customer’s requirements are fully met, and that additional instruments are easily interfaced with the flumes.
Flume
Size |
Max.
Upstream |
Min.
Head |
Minimum Flow Range
|
Max.
Head |
Maximum Flow Rate
|
||||
Inches
|
Slope %
|
Feet
|
CFS
|
MGD
|
GPM
|
Feet
|
CFS
|
MGD
|
GPM
|
4
|
2.2
|
0.02
|
0.001
|
0.001
|
0.56
|
0.25
|
0.121
|
0.078
|
54.5
|
6
|
2.2
|
0.03
|
0.004
|
0.002
|
1.68
|
0.35
|
0.295
|
0.19
|
132
|
8
|
2
|
0.03
|
0.008
|
0.005
|
3.43
|
0.50
|
0.69
|
0.445
|
310
|
10
|
1.8
|
0.05
|
0.014
|
0.009
|
6.17
|
0.60
|
1.12
|
0.722
|
502
|
12
|
1.6
|
0.05
|
0.016
|
0.011
|
7.35
|
0.70
|
1.68
|
1.08
|
752
|
15
|
1.5
|
0.06
|
0.027
|
0.017
|
12.10
|
0.90
|
3.09
|
1.99
|
1385
|
18
|
1.4
|
0.08
|
0.051
|
0.033
|
22.70
|
1.05
|
4.61
|
2.98
|
2070
|
21
|
1.4
|
0.10
|
0.081
|
0.052
|
36.50
|
1.25
|
7.04
|
4.54
|
3160
|
24
|
1.3
|
0.10
|
0.096
|
0.062
|
43.00
|
1.40
|
9.47
|
6.11
|
4250
|
27
|
1.3
|
0.11
|
0.126
|
0.081
|
56.40
|
1.60
|
13.1
|
8.44
|
5870
|
30
|
1.3
|
0.20
|
0.346
|
0.223
|
155.00
|
1.75
|
16.5
|
10.7
|
7410
|
Typical Options