Votre leader canadien en instrumentation depuis 1946.

IN-FLOW CTA-Débitmètres/régulateurs de débit industriels,directs

IN-FLOWCTA Series Mass Flow Meters/Controllers are modular instruments of rugged design according IP65 (dust- and waterproof). They can be combined with integrated or close-coupled control valves to form compact digital Mass Flow Controllers, whereby flow ranges are measured and controlled from lowest range 10 … 200 mln/min up to highest range  50 … […]

Posez une question sur ce produit

IN-FLOWCTA Series Mass Flow Meters/Controllers are modular instruments of rugged design according IP65 (dust- and waterproof). They can be combined with integrated or close-coupled control valves to form compact digital Mass Flow Controllers, whereby flow ranges are measured and controlled from


lowest range 10 … 200 mln/min

up to highest range  50 … 5000 ln/min


Through-flow measurement


Mass Flow Meters of the IN-FLOWCTA series work on the basis of direct through-flow measurement (no by-pass), following the constant temperature anemometer principle. The instruments contain no moving parts and have no obstructions to the flow path, which makes them ideal for low pressure drop applications and virtually insensitive to moisture or particulates.


Flow control


The control valve can be furnished as an integral part of a mass flow controllers or as a separate component. It is a proportional, electro magnetic control valve with fast and smooth flow control characteristics. With reference to the specific fields of application there are different series of unique Bronkhorst High-Tech control valves, for high or low flow, for high or low pressure difference. The standard valves are normally closed and are available up to Kv-values of 6.0. Normally opened valves can also be supplied.


Digital = Standard


The instruments have analog I/O-signals and also an RS232 connection as a standard feature. In addition to this there is the possibility of integrating an interface board with DeviceNet™, PROFIBUS DP, Modbus or FLOW-BUS protocol. The basic pc-board features integrated PID Control and various alarm and diagnostic functions. More information about digital "multibus" communication.


Features


  • Virtually insensitive to moisture or particulates
  • Low pressure drop
  • Accuracy: 1% of FS plus 1% RD 
  • Rangeability up to 1 : 100
  • Rugged, weatherproof housing (IP65, dust and waterproof)
  • Option: ATEX approval for Zone 2 (model T23 excluded)
  • Analog or digital communication (RS232 or fieldbus interface)



Flow capacities (based on air)











Mass Flow Meter

Ranges

Series T10 min. 0,01 … 0,2 ln/min

max. 0,02 … 2 ln/min
Series T11 min. 0,02 … 1 ln/min

max. 0,05 … 5 ln/min
Series T12 min. 0,1 … 5 ln/min

max. 0,5 … 50 ln/min
Series T13 min. 0,4 … 20 ln/min

max. 4 … 200 ln/min
Series T14 min. 2 … 100 ln/min

max. 10 … 1000 ln/min
Series T15 min. 10 … 500 ln/min

max. 50 … 5000 ln/min


 


 








Mass Flow Controller

Ranges

Series T20 (Kv-max 6.6E-2) min. 0,01 … 0,2 ln/min

max. 0,04 … 2 ln/min
Series T21 (Kv-max 6.6E-2) min. 0,02 … 1 ln/min

max. 0,1 … 5 ln/min
Series T22 (Kv-max 6.6E-2) min. 0,1 … 5 ln/min

max. 1 … 50 ln/min
Series T23 (Kv-max 3.5E-1) min. 0,4 … 20 ln/min

max. 4 … 200 ln/min


 


 


 









Typical combinations of Mass Flow Meters with close coupled Control Valves

Ranges

T13 + F- 002AI up to 4 … 200 ln/min;

Kv-max. 0,4
T13 + F- 004AI up to 4 … 200 ln/min;

Kv-max. 0,3
T14 + F- 003AI up to 20 … 1000 ln/min;

Kv-max. 1,5
T14 + F- 004BI up to 20 … 1000 ln/min;

Kv-max. 1,0
T15 + F- 003BI up to 100 … 5000 ln/min;

Kv-max. 6,0


 