Votre leader canadien en instrumentation depuis 1946.

QuikSert – Débitmètre à turbine, en ligne

The Blancett QuikSert® In-line Turbine Flow Meter provides the high accuracy and rigorous design of the standard Blancett turbine, but in a wafer-style mounting configuration. With a unique "between-the-flange" design, the need for mating flanges is eliminated, saving installation time and cost, and allowing for limited space requirements. The meter features a 316 stainless steel […]

  • SKU : I-B39-QuikSert
  • Fabricant : Blancett
Posez une question sur ce produit

The Blancett QuikSert® In-line Turbine Flow Meter provides the high accuracy and rigorous design of the standard Blancett turbine, but in a wafer-style mounting configuration. With a unique "between-the-flange" design, the need for mating flanges is eliminated, saving installation time and cost, and allowing for limited space requirements. The meter features a 316 stainless steel housing and rotor support, CD4MCU stainless steel rotor, and abrasion-resistant tungsten carbide rotor shaft and bearings. For fluid models, precision upstream and downstream flow straighteners ensure a high degree of measurement accuracy.


Operating Principle


Fluid and gas passes through a turbine, causing the turbine to rotate at a speed proportional to velocity. As each turbine blade passes through the magnetic field generated by the meter's magnetic pick-up, an AC voltage pulse is generated. These pulses provide an output frequency that is proportional to volumetric flow.


Specifications


  • Accuracy(Fluid):

    • ±1% of reading for 7/8" and larger meters;
    • ±1% of reading over the upper 70% of the measuring range for 3/8", 1/2" and 3/4" meters

  • Accuracy (Gas): ±2% of reading over the specified measuring range
  • Repeatability: ±0.1%(Fluid), ±0.5%(Gas)
  • Operating Temperature:   

    • -150…350°F (-101…177°C) (Fluid Standard)
    • Temperatures to 425°F (232°C) (Fluid with high-temp pick-up)
    • -40…330°F (-40…330°C) (Gas)

  • Turndown Ratio: About 10:1
  • End Connections: Wafer-style, ASME/ANSI B16.5-1996


 





















Part Number Meter Size x Flange Size Flow Ranges GPM Flow Ranges BPD Typical K-factor pulses/gallon
B131-038 3/8" x 1" 0.60 – 3.00 20-100 18,000
B131-050 1/2" x 1" 0.75-7.50 25-250 13,000
B131-075 3/4" x 1" 2.0-15.0 68-515 3,300
B131-088 7/8" x 1" 3.0-30.0 100-1000 3,100
B131-100 1" x 1" 5.0-50.0 170-1700 870
B132-050 1/2" x 2" 0.75-7.50 25-250 13,000
B132-075 3/4" x 2" 2.0-15.0 68-515 3,300
B132-088 7/8" x 2" 3.0-30.0 100-1000 3,100
B132-100 1" x 2" 5.0-50.0 170-1700 870
B132-150 1-1/2" x 2" 15-180 515-6000 310
B132-200 2" x 2" 40-400 1,300-13,000 48
B133-300 3 x 3" 60-600 2,100-21,000 57
B134-400 4" x 4" 100 – 1,200 3,400 – 41,000 29
B136-600 6" x 6" 200 – 2,500 6,800 – 86,000 7
B138-800 8" x 8" 250 – 3,500 8,500-120,000 3
B139-900 10" x 10" 500 – 5,000 17,150-171,500 1.6