Votre leader canadien en instrumentation depuis 1946.

Reid – Bain de pression de vapeur, 4 unités

Vapor pressure is a critical factor in the handling and performance of liquid petroleum and liquefied petroleum gas (LPG) products. The vapor pressure of automotive gasolines is subject to governmental regulation for pollution control purposes. Features and Benefits Conforms to ASTM D323, D1267 and related specifications Free standing or flush-mount benchtop installation […]

Posez une question sur ce produit
Vapor pressure is a critical factor in the handling and performance of liquid petroleum and liquefied petroleum gas (LPG) products. The vapor pressure of automotive gasolines is subject to governmental regulation for pollution control purposes.



Features and Benefits

  • Conforms to ASTM D323, D1267 and related specifications
  • Free standing or flush-mount benchtop installation
  • Microprocessor programmable high accuracy temperature control


Constant temperature water baths designed for Reid Vapor Pressure determinations of liquid petroleum products and liquefied petroleum gases (LPG). Immerses vapor pressure apparatus at the proper depth per ASTM specifications. Controls bath temperature with ±0.2°F (±0.1°C) precision. Microprocessor PID control provides quick temperature stabilization without overshoot, and the bath is protected by an overtemperature control circuit that interrupts power should bath temperature exceed a programmed cut-off point. Dual LED displays provide actual and setpoint temperature values in °C/°F format. Communications software (RS232, etc.), ramp-to-set and other enhanced features are available as extra cost options. Contact your Koehler representative for information. Double-wall construction with fiberglass insulated stainless steel tank. A sturdy 1" (25mm) flange permits flush-mount benchtop installation for easy access to the bath interior. Built-in holders suspend test cylinders at the required depth. Equipped with overflow stand pipe/drain.



Test apparatus for liquid products (ASTM D323) requires:

Test Cylinders, one or two-opening type

Pressure Gauges

Constant Temperature Bath

Bath Thermometer

Transfer Connection

Manometer

Manometer Adapter



Test apparatus for liquefied petroleum gases (ASTM D1267) requires:

Test Cylinders, two-opening type

Bleeder Valve Assemblies

Pressure Gauges

Constant Temperature Bath

Bath Thermometer

Flexible Tubing


 


Specifications

  • Conforms to: ASTM D323, D1267; GPA 2140; IP 69, 161; ISO 3007, 4256; DIN 51616, 51754; FTM 791-1201; NF M 07-007, 41-010
  • Capacity: 1 to 4 vapor pressure apparatus, one-opening or two-opening type
  • Temperature Control Stability: ±0.2°F (±0.1°C)
  • Maximum Temperature: 212°F (100°C)
  • Bath Medium: 13.7gal (51.9L) water


Accessories














Catalog

Number

Product Description

250-000-18F

ASTM 18F Thermometer

Range: 94 to 108°F

250-000-18C

ASTM 18C Thermometer

Range: 34 to 42°C

250-000-65F

ASTM 65F Thermometer

Range: 122 to 176°F

250-000-65C

ASTM 65C Thermometer

Range: 50 to 80°C
K11810 Transfer Connection

Consists of threaded brass cup, delivery tube, and sampling tube. Use for removing liquid from the sample container in accordance with ASTM specifications.
371-000-002 Mercury Manometer

Graduated in cm (1mm div.) and inches (0.1" div.). For checking pressure gauge reading up to 15psi.
K112B-1-0-12 Manometer Adapter

Attaches to pressure gauge for checking with mercury manometer.
AS568-210 O-Ring Seal

For coupling between air and gas chambers on K11500 and K11201 vapor pressure bombs.
AS568-113 O-ring Seal

For gauge and bleeder valve assembly connections on K11500 and K11201 vapor pressure bombs.
K40100 Flexible Tubing

Sulfur-free plastic lined tubing with 1/4" stainless steel and aluminum connectors. For charging LPG test cylinder.