Material: Alloy steel with PVC Protection Rated Capacities: 500kg, 1t, 2t, 3t, 5t, 10t, 20t, 30t, 50t, 100t Full Scale Output: 2mV/V ± 0.25% Safe Overload: 200% of full scale Breaking Overload: 500% of full scale IP Rating: IP67 NTEP 1:3000 Class III, Single Cell certified from 500kg-3t NTEP 1:5000 Class III, Multiple Cell certified […]
Rated Capacity | 500kg, 1t, 2t, 3t, 5t, 10t, 20t, 30t, 50t, 100t |
Full Scale Output | 2mV/V ± 0.25% |
Zero Balance | ± 0.02mV/V |
Non-linearity | < ± 0.03% |
Repeatability | < ± 0.03% |
Hysteresis Error | < ± 0.03% |
Creep in 30 minutes | < ± 0.03% |
Input Resistance | 1100Ω ±50Ω |
Output Resistance | 1000Ω ± 10Ω |
Recommended Excitation | 10V (15V Maximum) |
Insulation Resistance | > 2GΩ (50V DC) |
Temperature Effect on Sensitivity | < ±0.004% of Cn/k |
Temperature Effect on Zero Balance | < ± 0.005% of Cn/k |
Compensated Temperature Range | –10°C to 50°C/14°F to 122°F |
Service Temperature Range | –30°C to 70°C/-22°F to 158°F |
Storage Temperature Range | -50°C to 85°C/-58°F to 185°F |
Safe Overload | 200% of full scale |
Breaking Overload | 500% of full scale |
Seal Type | Environmentally sealed |
IP Rating | IP67 |