$104.00
Measure temperature in air, water, or soil with the 6.1m (20 ft) TMC20-HD temperature sensor. This product is designed to be used with HOBO U-Series, UX120-006M external-channel data loggers or ZW series wireless datanodes. This sensor records temperatures between -40° and 50°C (-40° to 122°F) in water or soil, and between -40° and 100°C (-40° to 212°F) in air. This product provides a response time of minutes typical to 90% in air moving 1 m/sec (2.2 mph); and 1 minute typical to 90% response time in stirred water. Please note, accuracy and resolution depend on data logger.
Measure temperature in air, water, or soil with the 6.1m (20 ft) TMC20-HD temperature sensor. This product is designed to be used with HOBO U-Series, UX120-006M external-channel data loggers or ZW series wireless datanodes. This sensor records temperatures between -40° and 50°C (-40° to 122°F) in water or soil, and between -40° and 100°C (-40° to 212°F) in air. This product provides a response time of minutes typical to 90% in air moving 1 m/sec (2.2 mph); and 1 minute typical to 90% response time in stirred water. Please note, accuracy and resolution depend on data logger.
This sensor operates in indoor, outdoor and underwater environments.
The TMC20-HD sensor supports the following measurements: Temperature and Water Temperature
Measurement range: -40° to 50°C (-40° to 122°F) in water; -40° to 100°C (-40° to 212°F) in air
Accuracy:
w/U12: ±0.25°C from 0° to 50°C (±0.45°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum;
w/ZW: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum;
w/UX120-006M: ±0.15°C from 0° to 70°C (±0.27°F from 32° to 158°F), insert probe 2.3 cm (0.9 inches) minimum;
Resolution:
w/U12: 0.03° at 20°C (0.05° at 68°F);
w/ZW: 0.02°C at 25°C (0.04°F at 77°F);
w/UX120-006M: 0.002° at 25°C (0.003° at 77°F);
Drift: <0.1°C (<0.2°F) per year
Response time in air: 2 min. typical to 90% in air moving 1 m/sec (2.2 mph)
Response time in stirred water: 30 sec. typical to 90%.
Operating range: Sensor tip and cable immersion in fresh water up to +50°C (122°F) for 1 year
Housing: Copper-plated sensor tip
Dimensions: 5.1 x 33 mm (0.2 x 1.3 inches)
Weight: 34 g (1.1 oz)
USB Data Loggers – requires external sensor(s)
UX120-006M 4-Channel Analog Data Logger
USB Data Loggers – optional external sensors
U12-013 Temperature/Relative Humidity/2 External Channel Data Logger
Wireless Data Nodes – via receiver/USB
ZW-006 Four Analog Port Data Node
ZW-007 Temperature/Relative Humidity/2 External Channels Data Node
ZW-008 Four External Channel Data Node