Canada’s Instrumentation Leader Since 1946.

Air/Water/Soil Temperature (20′ cable) Sensor

$104.00

Measure temperature in air, water, or soil with the 6.1m (20 ft)  TMC20-HD temperature sensor. This product is designed to be used with HOBO U-Series, UX120-006M external-channel data loggers or ZW series wireless datanodes. This sensor records temperatures between -40° and 50°C (-40° to 122°F) in water or soil, and between -40° and 100°C (-40° to 212°F) in air. This product provides a response time of minutes typical to 90% in air moving 1 m/sec (2.2 mph); and 1 minute typical to 90% response time in stirred water. Please note, accuracy and resolution depend on data logger.

Contact us for details
Important Info

Overview

Measure temperature in air, water, or soil with the 6.1m (20 ft)  TMC20-HD temperature sensor. This product is designed to be used with HOBO U-Series, UX120-006M external-channel data loggers or ZW series wireless datanodes. This sensor records temperatures between -40° and 50°C (-40° to 122°F) in water or soil, and between -40° and 100°C (-40° to 212°F) in air. This product provides a response time of minutes typical to 90% in air moving 1 m/sec (2.2 mph); and 1 minute typical to 90% response time in stirred water. Please note, accuracy and resolution depend on data logger.

Highlighted Features

  • Plug directly into the external input jacks of U12, UX120, or ZW Family loggers to expand the range of measurement options and applications

In what environment does this sensor operate?

This sensor operates in indoor, outdoor and underwater environments.

What measurements does this sensor support?

The TMC20-HD sensor supports the following measurements: Temperature and Water Temperature

Specifications

Measurement range: -40° to 50°C (-40° to 122°F) in water; -40° to 100°C (-40° to 212°F) in air
Accuracy:
w/U12: ±0.25°C from 0° to 50°C (±0.45°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum;
w/ZW: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum;
w/UX120-006M: ±0.15°C from 0° to 70°C (±0.27°F from 32° to 158°F), insert probe 2.3 cm (0.9 inches) minimum;
Resolution:
w/U12: 0.03° at 20°C (0.05° at 68°F);
w/ZW: 0.02°C at 25°C (0.04°F at 77°F);
w/UX120-006M: 0.002° at 25°C (0.003° at 77°F);
Drift: <0.1°C (<0.2°F) per year
Response time in air: 2 min. typical to 90% in air moving 1 m/sec (2.2 mph)
Response time in stirred water: 30 sec. typical to 90%.
Operating range: Sensor tip and cable immersion in fresh water up to +50°C (122°F) for 1 year
Housing: Copper-plated sensor tip
Dimensions: 5.1 x 33 mm (0.2 x 1.3 inches)
Weight: 34 g (1.1 oz)

Compatible Items

USB Data Loggers – requires external sensor(s)

U12-008  4-Channel External Data Logger

UX120-006M  4-Channel Analog Data Logger

USB Data Loggers – optional external sensors

U12-012  Temperature/Relative Humidity/Light/External Data Logger

U12-013 Temperature/Relative Humidity/2 External Channel Data Logger

Wireless Data Nodes – via receiver/USB

ZW-005  Four-Channel Data Node

ZW-006  Four Analog Port Data Node

ZW-007  Temperature/Relative Humidity/2 External Channels Data Node

ZW-008  Four External Channel Data Node

Email
Phone:
+1-800-665-5871
Our Offices