AN-WD2 Combined Wind Speed and Direction Sensor (cables available separately). Three cup anemometer closes magnetic reed switch. Wind vane connected to a 10K potentiometer. Suitable for GP2 and DL2e data loggers. Detachable cables have to be ordered separately – and are available in a range of lengths – see accessories. Full Details Here […]
Type |
Sensor |
Measuring range |
Accuracy and resolution |
Output range |
Sensitivity |
Operating temp. range |
Power requirement |
Cable details |
AN‐WD2 |
Speed |
0.4 to 75 m.s‐1 (0‐167 mph) |
±0.1 m.s‐1 if < 10.1 m.s‐1 ±1.1% if > 10.1 m.s‐1 starting threshold 0.4 m.s‐1 |
0 to 75 m/s |
0.8 Hz per m.s‐1 |
‐30 to +70 C (minimal icing) |
None |
|
Direction |
0‐360° mechanical 0‐356° electrical |
±4 degrees 0.5° (resolution) starting threshold 0.4 m.s‐1 |
0‐3V = 0‐356 degrees |
28 Ω per degree |
3V±0.2 VDC * |
|||
AN1 |
Speed |
0.2 ‐ 75 m.s‐1 (170 mph) |
1% ±0.1 m.s‐1 (0 ‐ 55 m.s‐1) 2% (>55 m.s‐1) |
0.2 to 60 Hz |
0.8 Hz per m.s‐1 |
‐30 to+70°C |
None |
3m/2w |
AN3 |
Speed |
0.15 ‐ 75 m.s‐1 |
1% ±0.01 m.s‐1 (pulsed)
1% (analogue) |
3 to 1500 Hz
0 ‐ 2.5 VDC |
20 Hz per m.s‐1
33 mV per m.s‐1 |
‐30 to +70C (minimal icing) |
7‐28 VDC
2.0 mA max |
3m/6w |
AN4 |
Speed |
0.5 ‐ 40 m.s‐1 max 60 m.s‐1 |
±5% ±0.5 m.s‐1 (0‐40 m.s‐1) |
0.5 to 50 Hz |
1.25 Hz per m.s‐1 |
25° to +60°C (free of ice) |
None |
5m/2w |
WD1 |
Direction |
0 to 358 degrees |
0.3 degrees (resolution) ±2° in winds >5 m.s‐1 starting threshold 0.6 m/s, 45° to flow. |
0 to 1000 Ω nominal |
2.8 Ω per degree |
‐50 to +70°C |
20 V max 20 mA max |
3m/6w |
Copyright - 2024 - Hoskin Scientific