Anemometer, reed switch activated by non‐ contact magnet. 3 cup rotor. Full Details Here Type Sensor Measuring range Accuracy and resolution Output range Sensitivity Operating temp. range Power requirement Cable details AN‐WD2 Speed 0.4 to 75 m.s‐1 (0‐167 mph) ±0.1 m.s‐1 if < 10.1 m.s‐1 ±1.1% if > 10.1 m.s‐1 starting threshold 0.4 m.s‐1 0 […]
Type |
Sensor |
Measuring
range |
Accuracy and resolution |
Output
range |
Sensitivity |
Operating
temp. range |
Power
requirement |
Cable
details |
Speed |
0.4
to 75 m.s‐1 (0‐167
mph) |
±0.1
m.s‐1 if
< 10.1 m.s‐1 ±1.1%
if > 10.1 m.s‐1 starting
threshold 0.4 m.s‐1 |
0
to 75 m/s |
0.8
Hz per m.s‐1 |
‐30
to +70 C (minimal icing) |
None |
|
|
Direction |
0‐360° mechanical
0‐356° electrical |
±4
degrees 0.5°
(resolution) starting
threshold 0.4 m.s‐1 |
0‐3V
= 0‐356 degrees |
28
Ω per degree |
3V±0.2
VDC * |
|||
Speed |
0.2
‐
75 m.s‐1 (170 mph) |
1%
±0.1 m.s‐1 (0
‐
55 m.s‐1) 2%
(>55 m.s‐1) |
0.2
to 60 Hz |
0.8
Hz per m.s‐1 |
‐30
to+70°C |
None |
3m/2w |
|
Speed |
0.15 ‐
75 m.s‐1 |
1%
±0.01 m.s‐1 (pulsed)
1%
(analogue) |
3
to 1500 Hz
0
‐
2.5 VDC |
20
Hz per m.s‐1
33
mV per m.s‐1 |
‐30
to +70C (minimal icing) |
7‐28
VDC
2.0
mA max |
3m/6w |
|
Speed |
0.5 ‐
40 m.s‐1 max
60 m.s‐1 |
±5%
±0.5 m.s‐1 (0‐40
m.s‐1) |
0.5
to 50 Hz |
1.25
Hz per m.s‐1 |
25°
to +60°C (free
of ice) |
None |
5m/2w |
|
Direction |
0
to 358 degrees |
0.3
degrees (resolution) ±2°
in winds >5 m.s‐1 starting
threshold 0.6 m/s, 45°
to flow. |
0
to 1000 Ω nominal |
2.8
Ω per degree |
‐50
to +70°C |
20
V max 20
mA max |
3m/6w |
Copyright - 2024 - Hoskin Scientific