Wire Size Conductor Size Insulation Thickness Jacket Thickness Outer Diameter Net Weight AWG MM Inch MM inches inches MM kg/km 20 0.81 0.015 0.38 0.015 0.38 .092 x .154 2.3 x 3.9 21 Standard Roll Sizes (other lengths available upon request) M ft 30.5 100 305 1000 Available Thermocouple Wire TypesT, J, K SpecificationsConductors: Solid […]
Wire Size
Conductor Size |
Insulation Thickness |
Jacket Thickness |
Outer Diameter |
Net Weight |
||||
AWG |
MM |
Inch |
MM |
inches |
inches |
MM |
kg/km |
|
20 |
0.81 |
0.015 |
0.38 |
0.015 |
0.38 |
.092 x .154 |
2.3 x 3.9 |
21 |
Standard Roll Sizes (other lengths available upon request)
M |
ft |
30.5 |
100 |
305 |
1000 |
Available Thermocouple Wire Types
T, J, K
Specifications
Conductors: Solid or stranded thermocouple wire per ASTM E230 & ANSI MC96.1
Insulation: Flame retardant PVC
Construction: Parallel conductors
Jacket: Flame retardant PVC
Operating Temperature: -15F (-26C) to +221F (+105C) continuous
Limits of Error: Conforms to ASTM E230 and ANSI MC and ANSI MC 96.1
Colour Code: Conforms to ASTM E230, IEC 584 96.1 (International Color Codes Available)
Thermocouple | Temperature Range F | Standard Grade Limits | ||
Extension Grade Wire | F (C) | F (C) whichever is greater | ||
TX | 32 (0) to 212 (100) | ±1.8 (1) | ||
JX | 32 (0) to 400 (200) | ±4 (2.2) | ||
KX | 32 (0) to 400 (200) | ±4 (2.2) | ||
Special Grade Limits | ||||
F (C) whichever is greater | ||||
TTX | 32 (0) to 212 (100) | ±0.9 (0.5) | ||
JJX | 32 (0) to 400 (200) | ±2 (1.1) | ||
KKX | 32 (0) to 400 (200) | ±2 (1.1) |