Clora R Benchtop

The Clora R ® compact analyzer measures total chlorine in hydrocarbons such as aromatics, distillates, heavy fuels, crude oils, and water. This state-of-the-art technology complies with ASTM D7536 and D4929C and delivers unparalleled accuracy and precision for petroleum and petrochemical applications where simple, quick, and reliable analysis is critical.

  • SKU : GF45-403747-01
  • Manufacturer: XOS
Contact us for details
Analyze Total Chlorine with Unparalleled Precision

XOS’s next generation of analyzer provides unparalleled precision with enhanced UX, improved data management, and greater ease of use.

  • LIMS integration for data management and transfer
  • Custom sample presets to save data entry time and minimize data entry error on common samples
  • Bar code reader auto fills sample name to reduce data entry time
  • Storage capacity for more than 50,000 measurement results
  • Supports up to 30 calibration curves
  • USB connectivity in front and back for connecting to printer, keyboard, mouse, and memory stick
  • Supports USB and network printers
  • Large, easy-to-remove side panels for easy serviceability
  • Advanced error reporting and diagnostics
  • Optional Autosampler to maximize productivity: 8-cup 43mm standard cup or 10-cup Accucells model

 

Product Details

Applications

  • Total chlorine analysis in petroleum products, biofuels, aromatics, and other chemicals, and water
  • For refineries, petrochemical and additive plants, pipeline terminals, and test laboratories

Features

  • LOD: 0.13 mg/kg (ppm) at 300s, 0.09 mg/kg (ppm) at 600s for hydrocarbons, 0.3 mg/kg (ppm) at 300s, 0.2 mg/kg (ppm) at 600s for aqueous samples **
  • Dynamic Range: 0.13 mg/kg (ppm) to 4 wt%
  • Manual sulfur correction to correct for high sulfur interference
  • Easy to use:
    • Intuitive 10-inch touch screen
    • Just plug in and measure
    • Measurement time: 10-999 s
  • Low and high range available:
    • Low range: 0.13 mg/kg (ppm) – 3000 mg/kg (ppm)
    • High range: 0.3 wt% – 4 wt%
  • Extremely low maintenance: no gasses, heating elements, columns, or quartz tubing
  • Traditional XRF sample cups or XOS Accucells – decided at time of order
  • Small footprint

 

Specifications
Model: Clora R
Test Method: ASTM D7536 and D4929
Dimensions:
42 cm (h) x 40 cm (w) x 54 cm (d)
16.5 in (h) x 15.8 in (w) x 21 in (d)
Power:
100-120 VAC, 47-63 HZ at 5.0 Amps
200-240 VAC, 47-63 HZ at 2.5 Amps
Minimum Sample Cup Volume: Traditional – 5 ml, Accucells – 1 ml
Ambient Temperature Requirements: 5-40° C (40-104° F)
Optical Path: Vacuum
Excitation Source: 75 W air-cooled