Non Destructive Scanner for Flat Roof Leak Detection and Surveying.
The Tramex Dec Scanner is a mobile non-destructive impedance scanner designed for the instant surveying of moisture conditions in flat roofing and waterproofing systems per ASTM D7954.
The Dec Scanner roof moisture meter detects and measures leaks within the roofing structure. Featuring three ranges of sensitivity and with a maximum depth penetration of 6″ (152mm), the Dec Scanner enables the inspection of a variety of roof membranes and insulation thicknesses.
Readings are instant and a flat roof area of up to 100,000 square feet can be reasonably covered in a day.
As it is easy and safe to use with no regulatory restrictions or operating license required, the Dec Scanner is ideal for water leak detection and integrity testing in roofing materials.
Size: | 30”W x 15¾“D x 6¼”H (762 mm x 400 mm x 158 mm) |
Scanning area: | 24”W x 15.5”D (609 mm x 394mm) |
Carry case size: | 38”W x 20”D x 10”H (940mm x 508 mm x 270mm) |
Weight Dec Scanner: | 24.6 lbs (9.95 Kg) |
Weight Carry Case: | 21.9 lbs (9.9 Kg) |
Total Weight Dec Scanner in Carry Case: | 46.5 lbs (21.1 Kg) |
Outer packaging carton weight: | 4.4 lbs (2 Kg) |
Total shipping weight: | 51 lbs (23.1Kg) |
Dimensional shipping weight: | 66 lbs (30 Kg) |
Display: | Analog |
Measuring Range: | 0 to 100 |
Comparative Max. depth of penetration: | 6” (152 mm) |
Power Supply: | 2 x 9 Volt PP3 Batteries (included) |
Limitations: | Some EPDM, Butyl rubber roofing and other conductive roofing |
Range selection:
The Dec Scanner has an integrated and adjustable calibration ability allowing for precise comparative readings. There are 3 Ranges, and they should be selected as best suits the surface under test, for example:
Range 1 – Most suitable for single-ply and thin roof coverings such as PVC, Hypalon and other smooth surfaces where insulation is wet and moisture is close to the surface.
Range 2 – Most suitable for multi-ply built-up and modified systems, mineral surfaced felts, and other smooth or gravel surfaces where insulation is less wet and moisture is below the surface.
Range 3 – Most suitable for thicker roof coverings such as mastic asphalt, thick gravel and stone surfaced roofing
Copyright - 2025 - Hoskin Scientific