Technical parameters: -wiring «from left to right» 1: ex+, 2: sig+, 3: ex-, 4: sig- -sensor dimensions: 25mm x 13mm x 5mm -rated capacity: same as your structure «unlimited capacity» -total error: from .5% to 3% «based on the actual structure» -thermal output: 0.5 μ m/m degrees c (-1) -zero balance: + or – 1% […]

Contact us for details
Technical parameters:

-wiring «from left to right» 1: ex+, 2: sig+, 3: ex-, 4: sig-
-sensor dimensions: 25mm x 13mm x 5mm
-rated capacity: same as your structure «unlimited capacity»
-total error: from .5% to 3% «based on the actual structure»
-thermal output: 0.5 μ m/m degrees c (-1)
-zero balance: + or – 1% of full scale
-input: 1000 ohms + or – 3 ohms
-output: 1000 ohms + or – 3 ohms
-gauge factor: 2.12 ± 0.5%
-actual grid size of the strain gauge: 4mm x 4mm
-insulation impedance: less than 5000 mega ohms
-operating temperature range: -40 to +60 degrees c
-maximum safe overload: based on the actual structure
-unlimited overload: based on the actual structure
-excitation: from 1 to 12 volts dc
-maximum excitation: 15 volts dc
-protective cover material: stainless steel cover «optional»
-cable length: based on the customer’s request
-cable type: based on the customer’s request