Fixed-Mount Thermal Camera. FLIR A50 and A70 Thermal Image Streaming Cameras are the right choice for users who want camera control capabilities and image streaming over Ethernet, as well as flexibility to perform analytics and raw data collection on thermal characteristics using preferred software applications.
FLIR A50 and A70 Thermal Image Streaming Cameras are the right choice for users who want camera control capabilities and image streaming over Ethernet, as well as flexibility to perform analytics and raw data collection on thermal characteristics using preferred software applications. With options for Wi-Fi, an integrated visual camera, compressed radiometric image streaming, and ONVIF S compatibility (advanced version only), these small and lightweight fixed-focus automation cameras will optimize process control and quality assurance to improve yield, product quality, through-put time, and lower costs.
Product Available in FOV 29°, 51°, and 95°.
IMPROVE PRODUCTION AND QUALITY
Quickly access thermal characteristics, with up to 640 × 480 (307,200 pixels) resolution and ±2°C accuracy, allowing users to optimize production settings and product quality.
TROUBLE-FREE INTEGRATION
GigE Vision and GenICam compliant for camera control and thermal/visual image video streaming over Ethernet into third-party machine vision applications.
RUGGED AND EASY TO INSTALL
Install the lightweight, IP66 rated camera with M8/12 connectors in any location – with multiple mounting options.
Even the most demanding datasets can now get a fully-fledged upgrade with FLIR Research Studio. This premium, advanced thermal analysis software offers a simplified workflow for displaying, recording, and evaluating data from multiple FLIR cameras simultaneously – allowing operators to quickly interpret and understand critical information.
For more distinct data, FLIR Research Studio fuses visible imagery and infrared data to provide a rigorously detailed analysis of virtually any environment.
Digital I/O connector type: M12 12-pin A-coded, Male (shared with external power)
Digital Inputs: 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
Digital Output Purpose: Programmatically set; fault (NC)
Digital Outputs: 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
Encoding: RTSP video streaming: H.264 / MPEG4 / MJPEG RTSP radiometric streaming: compressed JPEG-LS, FLIR radiometric GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric
Ethernet: Interface Wired, Wi-Fi (optional)
WiFi: Optional feature purchased separately. RP-SMA, female connector
EMC: • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC – Earth-moving and building construction machinery) • EN ISO 14982 (EMC – Agricultural and forestry machinery)
f-number: 1.4
Image Fequency: 30 Hz
Thermal Sensitivity/NETD: <35 mK
Accuracy: ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
Alarm Functions: NA
Alarm Output: NA
The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.