Whether the goal is product testing or scientific research, heat can be an important indicator of how a system is functioning. The FLIR ETS320 is a non-contact thermal measurement system that pairs a high-sensitivity infrared camera with an integrated stand, for hands-free measurement of printed circuit boards and other small electronics. OVERVIEW Accuracy ±3°C […]
Whether the goal is product testing or scientific research, heat can be an important indicator of how a system is functioning. The FLIR ETS320 is a non-contact thermal measurement system that pairs a high-sensitivity infrared camera with an integrated stand, for hands-free measurement of printed circuit boards and other small electronics.
OVERVIEW | |
Accuracy | ±3°C or ±3% of reading for ambient temperature 10°C to 35°C (50°F to 95°F |
Detector Type | Uncooled microbolometer |
Directives and Regulations | Battery Directive 2006/66/EC, EMI/EMC Directive 2014/30/EU, WEEE Directive 2012/19/EC, RoHS2 Directive 2011/65/EC, FCC 47 CFR Part 15 Class B, REACH Regulation EC 1907/2006 |
Field of view (FOV) | 45° x 34° |
IR Resolution | 320 x 240 (76,800 pixels) |
List of Contents | Camera, mount, stand, power supply, USB cable, FLIR Tools+ software |
NETD | <60 mK |
Packaging Size | 2.9 kg (6.4 lb.) |
Spot Size Min. Focus | 170 µm |
CONNECTIONS & COMMUNICATIONS | |
Interface | USB Micro: data transfer to and from PC and Mac devices |
ENVIRONMENTAL | |
Emissivity Correction | Variable from 0.1 to 1.0 |
Emissivity Table | Table of pre-defined materials |
Operating Temperature Range | 10°C to 40°C (50°F to 104°F) |
Storage Temperature Range | -40°C to 70°C (-40°F to 158°F) |
Encapsulation & Shock & Vibration | IP 40 (IEC 60529) |
IMAGING & OPTICAL | |
Available Lenses | NA |
Camera f-number | f/1.5 |
Close-up Lenses/Microscopes | NA |
Fixed Focus Distance | 70 mm ± 10 mm |
Image Frequency | 9 Hz |
Non-radiometric IR video streaming | Uncompressed colorized video using USB |
Radiometric IR video streaming | Full dynamic to PC (FLIR Tools/Tools+) using USB |
Spectral Range | 7.5 – 13.0 µm |
MEASUREMENT & ANALYSIS | |
Area | Box with max/min |
Reflected apparent temperature correction | Automatic, based on input of reflected temperature |
Spot Meter | Center spot |
METER DATA | |
Camera size (L x W x H) | 22 x 15 x 30 cm (8.7 x 5.9 x 11.8 in) |
Camera weight incl battery | 0.575 kg (1.27 lbs) |
Display | 3 in, 320 x 240 pixel color LCD |
POWER | |
Battery operating time | Approx. 4 hours at 25°C (77°F) ambient temperature and typical use |
Battery type | Li-ion battery, charged in camera |
Charging Time | 2.5 hrs to 90% capacity |
STORAGE MEDIA | |
Image File Format | Standard radiometric JPEG, 14-bit measurement data included |
Copyright - 2024 - Hoskin Scientific