$144.00
This miniature data logger can record temperature and relative light levels. Complete with waterproof casing, this product is designed for indoor, outdoor, and underwater deployment. This model can store approximately 52,000 measurments of 10-bit readings. Use a solar radiation shield for accurate temperature measurement in sunlight. See RS1 Solar Radiation Shield (assembly required) and M-RSA (pre-assembled) Solar Radiation Shield. Note that using a solar radiation shield prevents the use of the light sensor.
This miniature data logger can record temperature and relative light levels. Complete with waterproof casing, this product is designed for indoor, outdoor, and underwater deployment. This model can store approximately 52,000 measurments of 10-bit readings. Use a solar radiation shield for accurate temperature measurement in sunlight. See RS1 Solar Radiation Shield (assembly required) and M-RSA (pre-assembled) Solar Radiation Shield. Note that using a solar radiation shield prevents the use of the light sensor.
This data logger operates in indoor, outdoor and underwater environments.
The UA-002-64 data logger supports the following measurements: Light Intensity, Temperature, and Water Temp
Measurement Range | |
Temperature: | -20° to 70°C (-4° to 158°F) |
Light: | 0 to 320,000 lux (0 to 30,000 lumens/ft2) |
Accuracy | |
Temperature: | ± 0.53°C from 0° to 50°C (± 0.95°F from 32° to 122°F), see Plot A in manual |
Light intensity: | Designed for measurement of relative light levels, see Plot D in manual for light wavelength response |
Resolution | |
Temperature: | 0.14°C at 25°C (0.25°F at 77°F), see Plot A in manual |
Drift: | Less than 0.1°C/year (0.2°F/year) |
![]() |
|
Response Time | |
Airflow of 2 m/s (4.4 mph): | > 10 minutes, typical to 90% |
Water: | 5 minutes, typical to 90% |
Time accuracy: | ± 1 minute per month at 25°C (77°F), see Plot B in manual |
![]() |
|
Operating Range | |
In water/ice: | -20° to 50°C (-4° to 122°F) |
In air: | -20° to 70°C (-4° to 158°F) |
Water depth rating: | 30 m from -20° to 20°C (100 ft from -4° to 68°F), see Plot C in manual |
![]() |
|
NIST traceable certification: | Available for temperature only at additional charge; temperature range -20° to 70°C (-4° to 158°F) |
Battery life: | 1 year typical use |
Battery Type: | CR2032 |
Memory | |
UA-002-08: | 8K bytes (approximately 3.5K combined temperature and light readings or events) |
UA-002-64: | 64K bytes (approximately 28K combined temperature and light readings or events) |
Materials: | Polypropylene case; stainless steel screws; Buna-N o-ring |
Weight: | 18 g (0.6 oz) |
Dimensions: | 58 x 33 x 23 mm (2.3 x 1.3 x 0.9 inches) |
CE: | The CE Marking identifies this product as complying with all relevant directives in the European Union (EU) |
SOFTWARE
Graphing & Analysis
COMMUNICATIONS
Data Offload – Base Stations – Shuttles – Couplers
MAINTENANCE
Batteries
Case Replacement Kit
Desiccants
ACCESSORIES
Carrying Case
Compliance Certificates
Data Offload – Base Stations – Shuttles – Couplers
NIST Setup & Certifications
Solar Radiation Shields