$477.00
A high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads by simply plugging office equipment, vending machines, and other devices into the logger
A high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads from office equipment, vending machines, and other devices. These devices can simply be plugged into the logger, and it will record all the key power parameters. This UL-certified logger provides 0.5% measurement accuracy with a measurement resolution of 1 watt, making it an ideal choice for building audits where detailed energy use data is required. The rugged housing is designed to withstand the rigors of real-world handling, providing reliable performance despite bumps, drops, and use under desks.
This data logger operates in an indoor environment.
The UX120-018 data logger supports the following measurements: AC Current, AC Voltage, Amps (A), Kilowatt Hours (kWh), Power Factor (PF), Volt-Amps (VA), Volts (V), Watt Hours (Wh) and Watts (W)
Note: The UX120-018 logger is intended for use on 15 AMP circuits (NEMA 5-15P) with a working voltage of 120V AC ±10% at 50/60Hz and a max power of 1800W. Indoor use only Insulation category 2 |
|
RMS Voltage Accuracy: | 0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle |
RMS Current Accuracy: | 0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle |
Active Power Accuracy: | 0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle |
Active Energy Accuracy: | 0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle |
Power Factor Accuracy: | ±0.02 |
Drift: | Up to 0.5% typical within 1 year |
Resolution: | Volts, rms 10mV Amps, rms 0.1mA Active Power 10mW down to 1 watt loads @ 120VAC Apparent Power 10mVA Power Factor 0.01 PF |
Operating Environment: | Logging: 5° to 40°C (41° to 104°F); 0 to 95% RH (non-condensing), up to 2,000 m (6,562 ft) altitude |
Operating Modes: | Meter or logging when launched with HOBOware |
Logging Rate: | 1 second to 18 hours, 12 minutes, 15 seconds |
Statistics Sampling Rate: | 60 Hz or 16.67 mS single-cycle |
Memory Modes: | Wrap when full or stop when full |
Start Modes: | Immediate, push button, date & time, or next interval |
Stop Modes: | When memory full, push button, or date & time |
Restart Mode: | Push button |
Time Accuracy: | ±1 minute per month at 25°C (77°F), see Plot A |
Power Source: | Line-powered with 0.92 m (3 ft) AC power cord or two AAA 1.5 V alkaline batteries, user replaceable |
Battery Life: | 2 years with line power; 6 months battery only (no line power) with logging rate of 1 minute or greater operating at 25°C (77°F) |
Memory: | 4 MB (1.4 million measurements, maximum) |
Download Type: | USB 2.0 interface Full Memory Download Time: Approximately 1.5 minutes |
LCD: | LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range |
Size: | 13.97 x 7.62 x 4.75 cm (5.5 x 3 x 1.87 in.) |
Weight: | 230.8 g (8.14 oz) |
Ratings: | IP50; UL Listed; UL Listed to Canadian safety standards |
Calibration: | This device has been calibrated using equipment that has been tested in accordance with ANSI C12.20 0.5%. |