​Standard Features

  • Overall diameter is only 16.5 inches (42 cm), so GLS fits easily into manholes as small as 18 inches (46 cm), and also easily drops into most offset manh​oles.
  • Dry weight is less than 25 lbs (12 kg), the lightest sampler in the ISCO line.
  • Hinged handle makes one-handed carrying a breeze.
  • ​The patented LD90 Liquid Presence Detector and ISCO pump revolution counting system deliver accurate, repeatable sample volumes time after time.

Applications

  • Wastewater effluent
  • Stormwater monitoring
  • CSO
  • Permit compliance
  • Pretreatment compliance

Options and Accessories

  • Composite Sampling bottle configurations (1-gallon or 2.5 gallon glass or plastic; 2 gallon ProPak disposable sampling system)
  • Power sources
  • Suction lines and strainer​​​​​

Specifications

​​​​​​​​​​​​​GLS Sampler

Size (Diam. x Height): 16.5 x 26.5 inches (42 x 67 cm)
Weight: 24.5 lbs (11.1 kg) (dry, less battery)
Sample bottles: 1.0 or 2.5 gallon polyethylene or glass container.
Power Requirements: 12 volts DC. (Supplied by battery or AC power converter.)

Pump

Intake purge: Purge before and after each sample.
Tubing life indicator: Provides a message to change pump tubing.
Intake suction tubing: Length 3 to 99 ft. (1 to 30 m), Vinyl or Teflon® lined, ID 0.375 in. or 0.250 in
Pump tubing life: 2,000 samples
Typical repeatability: ±10 ml
Maximum lift: 26 ft. (7.9 m)
Typical line velocity @ Head height: 2.9 ft./s @ 3 ft; 2.5 ft./s @ 10 ft; 1.9 ft./s @ 15 ft. (0.76 m/s @ 0.9 m; 0.76 m/s @ 3.1 m; 0.58 m/s @ 4.6 m)
Sample presence detector: Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights.
Operational Temperature: 32° to 120°F (0° to 49°C)

Controller

Enclosure: NEMA 4X, 6 IP67
Program storage: 1 sampling program (in non-volatile ROM)
Flowmeter signal input: 5 to 15 volt DC pulse or 25 millisecond contact closure.
Number of composite samples: Up to 500 maximum
Clock accuracy: 1 minute per month, typical, for Real Time Clock
Sampling modes: Uniform time, flow. (Flow mode is controlled by external flow meter pulses.)
Sample frequency: 1 minute to 9,999 minutes, in 1 minute increments. 1 to 9,999 flow pulses.
Sample volumes: Programmable 10 to 9,990 ml in 1 ml increments
Controller diagnostics: Tests for RAM, ROM, pump, and display