Canada’s Instrumentation Leader Since 1946.

Jerome® J605 Hydrogen Sulfide Analyzer

Advanced Portable Analyzer for Precise Hydrogen Sulfide Monitoring.  Jerome® J605 Hydrogen Sulfide Analyzer is the latest innovation in toxic gas detection, offering unmatched sensitivity and reliability. Housed in a lightweight, ergonomic case, the J605 sets a new standard for low-level, portable H₂S monitoring. With its industry-proven gold film sensor, the J605 provides accurate detection at levels as low as 3 parts per billion (ppb) with a remarkable resolution of 20 parts per trillion (ppt).

Contact us for details
Features
  • Ultra-Sensitive Detection: The Jerome J605 detects hydrogen sulfide (H2S) in air at levels as low as 3 parts per billion (ppb), with a resolution of 20 parts per trillion (ppt), providing highly accurate low-level detection.
  • Proven Gold Film Sensor: With over 35 years of field and laboratory validation, the proprietary gold film sensor ensures consistent and repeatable results across a wide range of applications.
  • Rugged Construction: The J605 is built to withstand tough environments, housed in a durable, ergonomically designed metal casing that ensures long-lasting performance.
  • Extended Battery Life: Enjoy up to 18 hours of battery life per charge, making the J605 reliable and ready for use whenever and wherever needed.
  • Advanced Data Logging: Onboard data logging stores up to 20,000 measurements, including date, time, and up to 80 locations, with easy data transfer via USB and SCADA interface capabilities through 4-20 mA output.
  • Versatile Application: Ideal for regulatory compliance, odor control at wastewater and landfill facilities, scrubber efficiency testing, and corrosion monitoring in control rooms, with a detection range of 3 ppb to 10 ppm.
  • Survey Mode: Continuously draw in air samples to sweep an area for hydrogen sulfide hot spots, enabling targeted corrective actions.
  • Field Regeneration: The J605 allows for battery-powered sensor regeneration in the field, extending testing capabilities without the need for downtime.
  • Intuitive Interface: Simple, menu-driven operation with easy-to-understand diagnostics and error detection, plus a USB interface for straightforward data transfer.

 

Why Choose the Jerome J605 Hydrogen Sulfide Analyzer?

Jerome® J605 combines ultra-sensitive detection with rugged portability, making it the ideal choice for industries requiring precise H₂S monitoring in challenging environments. Whether you’re managing odor control, ensuring regulatory compliance, or protecting critical infrastructure, the J605 delivers reliable performance when you need it most.

 

Applications
  • Regulatory Compliance and Permitting:
    Ensure adherence to environmental regulations with accurate H₂S monitoring.
  • Nuisance Odor Monitoring:
    Monitor and control odor emissions in wastewater treatment and landfill management.
  • Scrubber/Biofilter Efficiency Testing:
    Evaluate the performance of scrubbers and biofilters in removing H₂S from air streams.
  • Semi-Conductor Manufacturing:
    Monitor H₂S levels in cleanroom environments to prevent corrosion and contamination.
  • Control Room Corrosion Monitoring:
    Protect sensitive electronics and equipment from corrosive H₂S gases in control rooms.
  • Agriculture and Livestock Production:
    Manage H₂S emissions from manure storage and treatment facilities.
  • Geothermal Emissions Monitoring:
    Monitor and control hydrogen sulfide emissions from geothermal power generation.

 

Specifications
  • Detection Range:
    • 3 ppb (0.003 ppm) – 10 ppm
  • Resolution:
    • 20 ppt (0.02 ppb) *range dependent
  • Response Time:
    • Survey Mode: 12-27 seconds
    • Manual Mode: 12-27 seconds
    • Auto Mode: 12-53 seconds
  • Flow Rate:
    • 150 mL/min
  • Result Units:
    • ppm, ppb
  • Autosample Intervals:
    • 1, 2, 5, 10, 15, 30, 45, 60, 90, or 120 minutes
  • Integrated Data Storage:
    • Stores up to 20,000 test results, retaining date, time, and up to 80 locations
  • Display:
    • 3.5” (9 cm) backlit LCD
  • Battery:
    • Rechargeable NiMH with 18-hour life; charges in 3 hours
  • Power Requirements:
    • 12 VDC for the instrument
    • 100-240 VAC, 47-63 Hz, 1.3A for the AC power supply
  • Fuse:
    • Auto-resetting fuse
  • Operating Environment:
    • 0°C to 40°C, non-condensing, non-explosive
  • Output:
    • Digital: USB serial data to PC, printer, or USB flash drive
    • Analog: 4-20 mA passive current loop; accurate to 0.3% of output
  • Dimensions:
    • 11” L x 6” W x 6.5” H
    • (28 cm L x 16 cm W x 17 cm H)
  • Weight:
    • 5.4 lbs. (2.5 kg)
  • Warranty:
    • 1 year, factory parts and labor
  • Certifications:
    • TUV 61010, CE

 

Related Accessories
  • Battery Pack Assembly: Keep your instrument powered for extended use with this reliable battery pack.
  • Scrubber Filter, LFS: Essential for maintaining clean airflow and removing contaminants.
  • Scrubber Filter, LFD: Additional filtration for enhanced air purity and accurate readings.
  • Ammonia Filter: Protects the instrument from ammonia interference during measurements.
  • External Battery Pack: Provides additional power for prolonged field operations.
  • Hard-Sided Carrying Case: Durable protection for your instrument during transport.
  • Soft-Sided Carrying Case: Lightweight and flexible option for easy transport.
  • 10:1 Dilution Module: Allows precise dilution of samples for more accurate measurements.
  • Probe: High-quality probe designed for accurate sample collection and measurement.
  • Pack of 20 Fritware, .25 cm Diameter: Replacement fritware for maintaining sample integrity.
  • Acrodisc Filter, 25 mm: Ensures high-quality filtration during sample collection.
  • AC Power Supply/Charger: Reliable power source to keep your instrument charged and ready for use.
  • Line Cord, 115 VAC: Standard power cord for connecting your instrument to a power source.
  • Accessory Kit: Comprehensive kit including all essential accessories for optimal instrument operation.
  • Maintenance Kit: Keep your instrument in top condition with this essential maintenance kit.
  • Intake Kit: Complete setup for precise sample intake and analysis.
  • Jerome® Functional Test Module, 250 ppb, 115V: Validates the accuracy of your instrument with a 250 ppb test module.
  • Jerome® Functional Test Module, 30 ppb, 115V: Ensures the reliability of your instrument with a 30 ppb test module.
  • Zero Air Filter: Removes impurities from the air to ensure accurate measurements.
  • Scrubber Filter: Additional filtration to maintain the purity of samples.
  • Chlorine Filter: Specifically designed to remove chlorine from samples to prevent interference.