Canada’s Instrumentation Leader Since 1946.

Manual and Semi-automatic Analysers: Aniline Point

ASTM D611-A-B-C-D IP 2-A-B-C-D ASTM D611-A, IP 2-A – Aniline Point and Mixed Aniline Point of Petroleum Products and Hydrocarbon Solvents Method A is suitable for transparent samples with an initial boiling point above room temperature and where the aniline point is below the bubble point and above the solidification point of the aniline-sample mixture. […]

  • SKU : G-F81-LT/AP-215000
Contact us for details

ASTM D611-A-B-C-D
IP 2-A-B-C-D

ASTM D611-A, IP 2-A - Aniline Point and Mixed Aniline Point of Petroleum Products and Hydrocarbon Solvents

  • Method A is suitable for transparent samples with an initial boiling point above room temperature and where the aniline point is below the bubble point and above the solidification point of the aniline-sample mixture.
  • Method B, a thin-film method, is suitable for samples too dark for testing by Method A.
  • Methods C is for samples that may vaporize appreciably at the aniline point.
  • Method D is for samples that may vaporize appreciably at the aniline point, particularly suitable where only small quantities of sample are available.

Model
Specifications
Spare Parts

LT/AP-215000-A/M
Aniline Point ASTM D611-A

  • Electric heater device
  • Pyrex® jacket ∅ 40 × 175 mm height
  • Pyrex® test tube ∅ 25 × 150 mm height
  • Manual stirrer
  • Caps
  • Support
  • LAB-102-151: external jacket
  • LAB-102-152: test tube
  • LAB-102-153: manual stirrer
  • LAB-102-153/S: glass sleeve for metal stirrer
  • LAB-102-154/G: cork for external jacketed tube
  • LAB-102-154/P: cork for test tube

LT/AP-215000-B/M Aniline Point “Thin-film” ASTM D611-B

  • Electric heater device
  • 600 ml Pyrex® jar
  • Adjustable support for pumping motor
  • Gauged body pump made in Pyrex®
  • Control box with speed variator for pumping and sample stirring also controlling the intensity of a low voltage lamp
  • Blocking cover
  • Manual bath stirrer
  • Pyrex® cell
  • Stainless steel pump
  • Cooling coil
  • LAB-102-155: external jar
  • LAB-102-156: internal test cell
  • LAB-102-157: manual stirrer
  • LAB-102-158: pump body
  • LAB-102-159: pump rotor
  • LAB-150-033: lamps
LT/AP-215000-C/M
Aniline Point “Tube” ASTM D611-C
  • Electric heater device
  • Test tube 22 mm ∅ × 150 mm height
  • Caps
  • Support
  • LAB-102-160: test tube
  • LAB-102-161: thermometer tube
  • LAB-102-162: cork stopper
  • LAB-102-163: metal guard

LT/AP-215000-D/M
Aniline Point ASTM D611-D

  • Electric heater device
  • Test tube ∅ 22 mm
  • Caps
  • Support


  • LAB-102-163: metal guard
  • LAB-102-164: test bulb
  • LAB-102-165: sampling pipette

General Information
  • Power Supply - 220Vac 50/60 Hz
  • Dimensions - cm 40 × 50 × 60
  • Weight - kg 8

Thermometers

  • T-AS33C: thermometer ASTM 33C IP 20C
  • T-AS33F: thermometer ASTM 33F
  • T-AS34C: thermometer ASTM 34C IP 21C
  • T-AS34F: thermometer ASTM 34F
  • T-AS35C: thermometer ASTM 35C IP 59C
  • T-AS35F: thermometer ASTM 35F

General Accessories

  • LT/B-2470/BCA200: analytical balance
  • LT/DO-248000/N: natural ventilation oven
Email
Phone:
+1-800-665-5871
Our Offices