Canada’s Instrumentation Leader Since 1946.

Tamson Solidification Point Tester (TSPT)

The TSPT has been developed for the automated determination of the solidification point of industrial organic chemicals.The determination of the solidification point involves the determination of the time-temperature curve prior to solidification (cooling) and the determination of the horizontal or flattened portion of the solidification curve. The solidification point of industrial organic chemicals is used to determine the purity of the chemical.

  • SKU : GJ06-31T0520
  • Manufacturer: Tamson

The TSPT has been developed for the automated determination of the solidification point of industrial organic chemicals.The determination of the solidification point involves the determination of the time-temperature curve prior to solidification (cooling) and the determination of the horizontal or flattened portion of the solidification curve. The solidification point of industrial organic chemicals is used to determine the purity of the chemical. The TSPT determines the solidification point in an easy, objective and comfortable way. Due to the automated detection of the horizontal or flattened portion of the temperature cooling curve, the measurement will be performed with high accuracy and high repeatability.The TSPT has an integrated embedded Industrial PC and is using Windows¬Æ 10 based software. The TSPT is operated by using a keyboard. The test procedure, the parameter settings, the measurement and the data acquisition will be performed with the solidification-point software, where the settings for several test methods are predefined. All parameters can be set individually, so that the users are able to create their own test method. After the test, the measured values of the freezing curve will be stored and a test protocol can be printed out. The stored data can also be exported to a standard tabulation program (e.g. Excel¬Æ).The TSPT is equipped with a  compact cooling thermostat that enables the operator to conduct measurements down to -5°C. For more information on the cooler, please see the Tamson TLC15-5 specification sheet. The cooling circulator can be used either as a standalone unit or can be controlled via the solidification-point software. The installed gear motor for the stroke movement is also software controlled. The stroke rate is adjustable and can be set by the controller. During the measurement the motor will be automatically switched off after the temperature minimum has been detected.

The TSPT is capable to perform tests according to ASTM D852 and ASTM D6875.

The TSPT is available in the following voltages/frequencies:

  • TSPT 230V/50Hz (P/N: 31T0510)
  • TSPT 230V/60Hz (P/N: 31T0515)
  • TSPT 115V/60Hz (P/N: 31T0520)
Bath Accuracy 0.02°C
Bath Volume 5 L
Height 1100 mm
Width 440 mm
Length 420 mm
Minimum Temperature -5°C
Maximum Temperature +60°C