To measure the temperature profile in soils in six fixed depths. Inside a tube made of glass-fibre reinforced plastic (GRP) 6 temperature sensor elements are placed in different depths. Each sensor element has direct contact to a stainless steel ring which is embedded into the tube’s surface. This ensures that each sensor has direct contact […]
To measure the temperature profile in soils in six fixed depths.
Inside a tube made of glass-fibre reinforced plastic (GRP) 6 temperature
sensor elements are placed in different depths. Each sensor element has
direct contact to a stainless steel ring which is embedded into the
tube's surface. This ensures that each sensor has direct contact to the
soil. The 6 sensors are placed in the depths 5, 10, 20, 30, 50 and 100 cm.
The probe is completely inserted into the soil until the top edge of the
tube is on a level with the ground surface. The probe's cable will exit
the tube in a depth of 8 cm and then is buried below the ground
surface. Thus, thermal influences by the ambient temperature are
excluded.
The Th3-v has analogue output signals 0 to 1 V corresponding to -20 to
+50°C. Each depth requires an individual logger channel, thus 6 channels
need to be available.
The Th3-v can be connected directly to the PR1/2 plug of the DL6 6-channel logger with an extension cable EC-8.
The Th3-s is available with a seriel tensioLINK/SDI12 output and a 4-pin plug.