The new thicknessSENSOR is a sensor system for precise thickness measurement of strip and plate material. This fully assembled system comprises a stable frame on which two laser triangulation sensors are fixed that detect the thickness of various materials according to the difference principle. The evaluation unit integrated into the frame calculates the thickness values […]
Model | thicknessSENSOR 10/200 | thicknessSENSOR 10/400 | thicknessSENSOR 25/200 | thicknessSENSOR 25/400 |
Measuring range | 10mm | 10mm | 25mm | 25mm |
Working gap | 46mm | 46mm | 71mm | 71mm |
Measuring width | 200mm | 400mm | 200mm | 400mm |
Linearity (combined) | ±10μm | ±10μm | ±40μm | ±40μm |
Measuring rate | 0.25kHz / 0.5kHz / 1kHz / 2kHz / 4kHz | |||
Light source | semiconductor laser <1 mW, 670nm (red) | |||
Permissible ambient light | 10,000lx | |||
Light spot diameter max. | 140 x 160μm (±10%) | 140 x 160μm (±10%) | 390 x 500μm (±10%) | 390 x 500μm (±10%) |
Protection class | IP65 | |||
Laser safety class | Class 2 according to DIN EN 60825-1 : 2008-05 | |||
Temperature stability | ±0.03% FSO/°C | |||
Operating temperature | 0°C... +50°C (non-condensing) | |||
Storage temperature | -20°C ... +70°C (non-condensing) | |||
Control inputs/outputs | 1 x trigger in / 1 x master / 2 x switching outputs | |||
Measurement value | 0 ... 5V, 0 ... 10V, ±5V, ±10V, 4 ... 20mA | |||
output | Ethernet | |||
Vibration | 2g / 20 ... 500Hz (according to IEC 60068-2-6) | |||
Shock | 15g / 6ms / 3 axes (according to IEC 60068-2-29) | |||
Weight | 3.3kg | 4.3kg | 3.5kg | 4.5kg |
Displays - Sensor | 3x color LEDs for power and status | |||
Displays - Controller | Power i.o. | |||
Operation Web interface |
Selectable averages / data reduction / setup management / limit values | |||
Power Supply | 11-30V DC, 24V P< 5W | |||
Electronics | integrated signal processor, signal processing unit | |||
Electromagnetic compatibility (EMC) | EN 61 000-6-3 / DIN EN 61326-1 (Class B) EN 61 000-6-2 / DIN EN 61326-1 |