Canada’s Instrumentation Leader Since 1946.

WATER DAMAGE RESTORATION INSPECTOR KIT – WDIK

Moisture and RH testing of building structures.

  • SKU : G643-WDIK
  • Manufacturer: Tramex
Contact us for details
Description

CREATE VISUAL MOISTURE MAPS AND REPORTS WITH TRAMEX METERS APP

The Tramex Water Damage Restoration Inspector Kit is the complete kit for moisture content and relative humidity testing and monitoring of ambient conditions, concrete, wood, tiles, drywall, plaster and numerous building materials after water damage.

Walls and floors

Featuring the Tramex ME5 for dual-depth, non-invasive testing of moisture conditions in drywall, wood, plaster, brick, tiles, resilient flooring, laminates and roofing. The ME5 has a dual-depth feature to allow for the elimination of substrate influence on readings.

Concrete

The Tramex CMEX5 digital concrete moisture meter allows for quantitative moisture content measurement using Gravimetric testing as a baseline, comparative testing of concrete and ambient conditions measurement. The CMEX5 incorporates a bayonet plug-in port for the heavy-duty pin-probe to measure moisture content in wood or WME in other building materials as well as Relative Humidity readings with the reusable Tramex Hygro-i2 RH probe.

Ambient conditions

The Tramex Feedback Datalogger gives live readings and time logs relative humidity, temperature and dew point in the environment and in materials and air spaces with the plug-in relative humidity probe. An infrared surface thermometer gives surface temperature and dew point conditions used in conjunction with the CMEX5 hygrometer.

Moisture mapping

Bluetooth connectivity to the Tramex Meters App allows for visualization of readings, moisture mapping and data reporting to mobile devices, to GeoTag test results, create, save and share photos, reports and charts, as well as see your meter screen on your phone when extending to hard to reach places.

The Tramex Water Damage Restoration Inspection Kit comes with an extension handle in a protective heavy-duty carrying case with die-cut foam lining.

 

Specifications

Concrete Moisture Encounter X5 – CMEX5 – Measuring Range:

Depth of penetration in concrete: approx.  ¾” (20mm)
Moisture content for Concrete: 0 → 6.9 %
Comparative for Gypsum floor screed: 0 → 12
CM Equiv Anhydrite/Concrete: 0→2.7 / 0→4.3
Reference scale: 0 → 100
Relative Humidity: 0 → 99%
(with optional Hygro-i2 ® probe): Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F
Moisture content for wood (with optional wood pin probes): 5 → 30 %

 

Moisture Encounter 5 – ME5 – Measuring Range: 

Wood Moisture Content: 5 to 30%
Reference scale for building materials: 0 to 100
Depth of penetration: Shallow signal: up to ⅜” (10mm)

Deep signal: up to 1¼” (30mm)

 

Feedback Datalogger DL-RHTX Measuring Range:

Memory: 100,000 data point entries (samples of Ambient RH and temperature; SurfaceTemperature)
Logging Rate: Logger interval adjustable between 10 minutes and 1 hour
Transmission Range: Up to 165ft (50m) line-of-sight
Bluetooth: BLE Bluetooth Low Energy 4.2 compliant

 

Relative Humidity Sensor Specifications:

Range: 0 to 100%RH
Accuracy: ±1.5%RH Range 0% to 80%RH ±2.0%RH Range 80% to 99%RH (@ 77ºF (25ºC))
Resolution: 0.1% over the complete range
Drift: <0.25%RH per year

 

Temperature Sensor Specifications:

Range: -4ºF to 158ºF( -20°C to 70°C)
Accuracy: ±0.1ºF Range -4ºF to 158ºF(±0.1 °C Range -20°C to 70°C)
Sensor Protection: PTFE Film protects sensor opening from water & dust Drift: <0.04ºF (0.03ºC) per year
Drift: <0.04ºF (0.03ºC) per year

 

Infrared Thermometer  IRT2

Temperature range: -58ºF ~ 1202ºF (-50 to 650 ºC)
Distance to Spot ratio: D:S = 12:1
Display resolution: 0.1 ºF(0.1ºC)   <1000 1ºC   >1000
Accuracy for targets: Assumes ambient operating temperature of  73 to 77ºF (23 to 25 ºC) -58ºF ~ 68ºF (-50 ~ 20ºC)

±4.5ºF (2.5ºC) 68ºF ~572ºF (20ºC ~300ºC)  ±1.0% ± 1.8ºF (1.0ºC) 572ºF ~ 1202ºF (300ºC ~650ºC) ±1.5%

Repeatability: -58~68ºF (-50~20ºC)  :  ± 2.3ºF (1.3ºC) 68~1202ºF (20~650ºC) : ±0.5% or ±0.9ºF (0.5ºC)
Response time: 150ms
Spectral response: 8~14um
Emissivity: Digitally adjustable from 0.10 to 1.0
Over range indication: LCD will show “—-”
Polarity: Automatic (no indication for positive polarity); Minus (-) sign for negative polarity
Diode laser output: <1mW,Wavelength 630~670nm, Class 2 laser product
Operating temp.: 32 to 122ºF ( 0 to 50ºC)
Storage temp.: 14 to 140ºF (–10 to 60ºC)
Relative humidity: 10%~90%RH operating, <80%RH storage
Power supply: 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
Safety: “ CE ” Comply with EMC

 

Specifications of Kit:

Size: 17.1” x 14.2” x 5.5” (43.5cm x 36cm x 14cm)
Weight: 8.6 lbs (3.9kg)
Power: 5 x AA batteries, 1 x 9 volt PP3 battery