$921.00
The F350 series is a versatile, high performance, air velocity and air temperature sensor where the sensor element is built remotely from the sensor electronics. In products where segregation of the sensing element and electronics is desirable, such as products involving high EMI sensitivity or extreme temperature, or those where the sensing area is too small for typical probe-style sensors. The sensor requires analog input option during RX3000 or U30 system configuration and use of a S-FS-CVIA when using the H22-001 data logger. When using a U12 data logger, this sensor requires an 0-5 Vdc analog input cable (CABLE-ADAP5) and external power provided by an AC adapter (AC-SENS-1).
The F350 series is a versatile, high performance, air velocity and air temperature sensor where the sensor element is built remotely from the sensor electronics. In products where segregation of the sensing element and electronics is desirable, such as products involving high EMI sensitivity or extreme temperature, or those where the sensing area is too small for typical probe-style sensors.
The sensor requires analog input option during RX3000 or U30 system configuration and use of a S-FS-CVIA when using the H22-001 data logger. When using a U12 data logger, this sensor requires an 0-5 Vdc analog input cable (CABLE-ADAP5) and external power provided by an AC adapter (AC-SENS-1).
This adds the ability for users to be able to measure air velocity (in ducts, e.g.) from which CFM can be computed.
This sensor operates in an indoor environment.
The T-DCI-F350-W5x3 sensor supports the following measurement: Air Velocity
Operating temperature range | 0°C to 60°C (32°F to 140°F) |
Velocity range | 0.15 to 1.0 m/s (30 to 200 fpm) |
Response time | 400ms |
Storage temperature | -40°C to 105°C (-40°F – 220°F) |
Relative humidity (non-condensing) | 5-95% |
Supply power requirements | 4.5-15 VDC, 35mA nominal |
Velocity Output | 0-5V |
Temperature output | 0-5V |
Housing Construction | Polycarbonate (PC), UL94-V0 (head) UL94-HB (housing) |
Plenum rated cable | 22 AWG |
Environmental Protection | IP65 electronics, including conformal coated sensing element |
Accuracy | 0.15 to 1.0 m/s (30 to 200 fpm): ± (1% of reading + 0.05 m/s [10 fpm]) 0.5 to 10 m/s (100 to 2,000 fpm): ± (4% of reading + 0.10 m/s [20 fpm]) 1.0 to 20 m/s (200 to 4,000 fpm): ± (5% of reading + 0.15 m/s [30 fpm]) |
Stainless Steel Wand | 127mm (5″) |
Sensor Head Height | 64mm (.25″) |
Housing Length | 196 mm [7.75″] |
Cable Length from Housing to Sensor Head | 1m [3′] |
Data Loggers
Bluetooth (BLE) Data Loggers
MX1104 Analog/Temp/RH/Light Data Logger
MX1105 4-Channel Analog Data Logger
USB Data Loggers – requires external sensor(s)
H22-001 H22 Energy Data Logger
U12-008 4-Channel External Data Logger
U30-NRCU 30 USB Weather Station Data Logger
UX120-006M 4-Channel Analog Data Logger
Web-based Monitoring Systems – via remote communication
RX3000 Remote Monitoring Station Data Logger
USB Data Loggers – optional external sensors
U12-012 Temperature/Relative Humidity/Light/External Data Logger
U12-013 Temperature/Relative Humidity/2 External Channel Data Logger
Copyright - 2024 - Hoskin Scientific